Explosion Proof Linear Lighting – SLE Series
The SLE Series explosion proof linear lighting fixtures are available with T8 fluorescent tubes, LED tubes and integrated LED strip configurations. Designed for industrial lighting projects in specified hazardous locations, the series features a GRP housing, polycarbonate diffuser and multiple mounting options.
With different wattages, light outputs and installation configurations, the SLE Series can be selected for applications such as paint spray booths, gas station canopies and industrial facilities, subject to the required hazardous-area classification and model certification.
Explosion Proof Led Linear Fluorescent Lights SLe Series
T8, LED Tube & LED Strip Options
The SLE Series offers T8 fluorescent, LED tube and LED strip configurations to meet different industrial lighting requirements.
Simple Ceiling Mounting
The ceiling mounting bracket supports straightforward installation. Additional pendant, wall and stanchion mounting options are available for different project requirements.
Impact-Resistant Polycarbonate Diffuser
The polycarbonate diffuser provides protection for the light source and is designed for demanding industrial lighting environments.
Cable Gland and Connection Options
The SLE Series offers 3/4-inch NPT or M25 × 1.5 cable entry options. Suitable certified cable glands should be selected according to the installation requirements.
Explosion Proof Led Linear Fluorescent Lights SLe Series
The SLE Series offers three lighting configurations for different industrial applications: T8 fluorescent tubes, LED tubes and integrated LED strips. Compare the options below to find a suitable configuration for your project requirements.
Traditional T8 fluorescent tube configurations for projects specifying fluorescent lighting in industrial environments.
Tube Wattage
18W / 36W
Single- and dual-tube models are listed in the selection table.
LED tube configurations for industrial lighting projects requiring linear illumination with LED technology.
Tube Wattage
9W / 18W
Available model listings include single- and dual-tube configurations.
Integrated LED strip configurations with different wattage options to meet various industrial lighting requirements.
Fixture Wattage Range
20W–80W
Compare available strip configurations according to your required light output.
Not sure which configuration suits your project? Share your hazardous-area classification, required light output, mounting type and quantity. Our team can help review suitable SLE models and technical specifications for your application.
INQUIRE NOW →Note: Model configurations and wattage ranges are based on the published SLE selection table. Final specifications, model availability and hazardous-location approvals should be confirmed before ordering.
| Model | Lumens | Wattage | Lumens per Watt | Equivalent HID Luminaire |
| SLe-T-1x18W | 1530 | T8 1x18W | 85 | 70W |
| SLe-T-2x18W | 3060 | T8 2x18W | 85 | 70-100W |
| SLe-T-1x36W | 3060 | T8 1x36W | 85 | 70-100W |
| SLe-T-2x36W | 6120 | T8 2x36W | 85 | 100-150W |
| SLe-L-1x9W | 1170 | LED 1x9W | 130 | 70W |
| SLe-L-2x9W | 2340 | LED 2x9W | 130 | 70-100W |
| SLe-L-1x18W | 2340 | LED 1x18W | 130 | 70-100W |
| SLe-L-2x18W | 4680 | LED 2x18W | 140 | 100-150W |
| SLe-S-1x20W | 2800 | LED 20W | 140 | 70-100W |
| SLe-S-1x30W | 4200 | LED 30W | 140 | 100W |
| SLe-S-2x15W | 4200 | LED 30W | 140 | 100W |
| SLe-S-1x40W | 5600 | LED 40W | 140 | 100-150W |
| SLe-S-2x20W | 5600 | LED 40W | 140 | 100-150W |
| SLe-S-2x30W | 8400 | LED 60W | 140 | 175-250W |
| SLe-S-2x40W | 11200 | LED 80W | 140 | 320-400W |
Explosion Proof Led Linear Fluorescent Lights SLe Series
Compliance | IEC Standard IEC60079-0, IEC60079-1,IEC60079-7, IEC60079-18, IEC60079-31 Ex eb mb db IIC T5/T6 Gb Ex tb IIIC T95℃/T85℃ Db IP66 Zone1, Zone 2 Zone 21, Zone 22 | |||||||
| EU Standard EN60079-0, EN60079-1, EN60079-7, EN60079-18, EN60079-31 II 2 G Ex eb mb db IIC T5/T6 Gb II 2 D Ex tb IIIC T95℃/T85℃ Db IP66Zone1, Zone 2 Zone 21, Zone 22 | ||||||||
| NEC & CEC Standard Class Ⅰ, Division 2, Groups A, B, C, D Class Ⅱ, Division 2, Groups F, G Class Ⅲ | ||||||||
| UL Standard UL844, UL1598, UL1598A | ||||||||
| CSA Standard CSA C22.2 No.137 | ||||||||
| Rated Voltage | 100-277V AC 50/60Hz 277-480V AC 50/60Hz | |||||||
| Wattage(W) | T8 1x18W | T8 2x18W | T8 1x36W | T8 2x36W | LED 1x9W | LED 2x9W | LED 1x18W | LED 2x18W |
| Lumens(LM) | 1530 | 3060 | 3060 | 6120 | 1170 | 2340 | 2340 | 4680 |
| Wattage(W) | LED 1x20W | LED 30W | LED 2x15W | LED 40W | LED 2x20W | LED 2x30W | LED 2x40W | |
| Lumens(LM) | 2800 | 4200 | 4200 | 5600 | 5600 | 5400 | 11200 | |
| Color Temperature | 5000K/4000K/2700K | |||||||
| IP Grade | Wet Locations, Type 4X, IP66 | |||||||
| Ambient Temperature | -40℃~ +55℃ /-40°F ~ +131°F | |||||||
| Cable Entry | NPT 3/4” or M25X1.5 | |||||||
| Terminals | Terminal blocks ≤ 2.5mm², cable diameter 10-14mm | |||||||
| Mounting Type | Flange Stanchion / Fence Stanchion / Ceiling / Pendant / Chain Hanging / Wall 30° / Wall 60° | |||||||
| Beam Angle | 120° / 90° / 60° / 40° | |||||||
SLE Series linear lighting fixtures are designed for industrial projects requiring reliable illumination in specified hazardous locations. Different lighting configurations and mounting options allow buyers to select suitable models according to their installation environment and project specifications.

Paint spray booths require suitable lighting for surface inspection and spraying operations. The SLE Series offers linear lighting configurations that can be considered for ceiling-mounted installations in classified areas, subject to the required hazardous-location approval.
Selection Focus: Area classification, fixture placement, required illumination and maintenance access.

Chemical production facilities may require linear lighting for processing workstations, inspection areas and equipment access points. SLE fixtures provide different light-source configurations and mounting arrangements for projects where hazardous-area lighting is specified.
Selection Focus: Gas or dust classification, mounting position, cable entry and operating conditions.

Selected areas within petrochemical and oil processing facilities require dependable lighting for operational access and equipment inspection. SLE linear fixtures can be evaluated for suitable installations where the specified model matches the site's hazardous-area classification.
Selection Focus: Hazardous-area approval, mounting method, light output and installation requirements.
Share your installation environment, hazardous-area classification, required mounting type and estimated quantity. SUREALL can help review suitable SLE configurations for your lighting requirements.
INQUIRE NOW →Application images are for illustration. Fixture selection must be based on the actual installation conditions and applicable model certifications.
Explosion Proof Led Linear Fluorescent Lights SLe Series
Ceiling Type
Pendant Type
Wall 60° Type
Wall 30° Type
Flange Stanchion Type
Fence Stanchion Type
Chain Hanging Type
Find answers to common questions about SLE Series lighting configurations, hazardous-area classifications, installation options and project quotation requirements.
The SLE Series includes three lighting configurations. SLe-T models use traditional T8 fluorescent tubes with 18W or 36W tube options. SLe-L models use LED tubes with 9W or 18W options, while SLe-S models feature integrated LED strip configurations with total fixture wattages from 20W to 80W. Buyers can compare the available models based on lighting technology, required light output and project specifications.
The published SLE technical specifications list classifications under IEC/EN and NEC/CEC systems, including Zone 1, Zone 2, Zone 21, Zone 22 and Class I, Division 2 applications. However, the applicable gas or dust group, temperature class and approval scope must be verified against the certification documents for the selected model. Please provide your project's hazardous-area classification so that the appropriate configuration and documentation can be reviewed before ordering.
The SLE Series lists seven mounting arrangements: ceiling, pendant, wall-mounted at 30 degrees, wall-mounted at 60 degrees, flange stanchion, fence stanchion and chain hanging. The appropriate option depends on the installation structure, fixture orientation and site conditions. Refer to the mounting diagrams above when planning the installation.
SLE LED tube and LED strip configurations may be considered when planning an upgrade from traditional T8 fluorescent lighting. However, replacement suitability depends on the existing fixture dimensions, electrical connections, mounting arrangement and hazardous-area certification requirements. Simply replacing fluorescent tubes with LED tubes inside an existing explosion-proof fixture should not be assumed to be permitted. The complete fixture and its approved configuration should be reviewed before making changes.
To receive a suitable model recommendation and quotation, please provide your preferred SLE configuration, required wattage or light output, hazardous-area classification, mounting method, supply voltage and estimated quantity. Details such as cable entry requirements, installation country and applicable certification standards will also help our team review the appropriate product configuration for your project.
Contact SUREALL with your lighting specifications, installation requirements and expected order quantity. Our team can assist with model selection and quotation inquiries.
Contact SUREALL for SLE Lighting Specifications and Pricing →Want to Get High-quality LED lighting, explosion proof lighting and other explosion-proof fittings? Welcome to SUREALL
+86-18153889015
+86-15388016808