Search
×

Explosion Proof Flood Light

Products Show for Explosion Proof Flood Lighting


High lumens output led flood lights and spotlight to provide illumination for large areas in harshest and hazardous environment

INQUIRE NOW

Explosion proof flood lighting, also called explosion proof led flood light, explosion proof spot light, led flood light hazardous area, atex floodlight, atex led floodlight, explosion proof led lights, share more than 35% requests for the family of explosion proof lighting, besides, explosion proof led flood light trend to replace up to 90% of explosion proof flood lighting.


Structured with a square shape widely for wide space and large area lighting used in high spot, central square with ultra high lumens and excellent lumens efficiency, explosion proof flood lighting normally are equipped with die cast aluminum flame proof housing and integrated led explosion lamp and driver to make it possible to be used as class 1 and class 2 light fittings meeting the class 1 div 1 to class 1 division 2 electrical requirements and dust proof hazard class division rating from class 2 division 1 to class 2 division 2 hazardous locations, atex rating from Zone 1 to Zone 2 areas. As a big and responsible explosion proof flood light factory, SUREALL produces high- quality explosion proof flood lighting which is the fundamental lighting for applications ranging from upstream oil and gas lighting, refinery lighting, paint booth lighting and gas station lights. Features in adjustable angle and wall, bracket mounted accessories, explosion flood lighting can be installed where you request bright lighting effectiveness.

Category

Explosion Proof Flood Light

Explosion Proof Led Flood Light Class 1 Div 1 Zone 1 SHF-I Series

Class I Division 1

Zone 1&2, Zone 21&22

Type 4X, IP66

View More
Explosion Proof Led Flood Light Class 1 Div 1 Zone 1 SHF-IA Series

Class I Division 1

Zone 1&2, Zone 21&22

LED 20-200W

Type 4X, IP66

View More
Explosion Proof Led Flood Light Class 1 Div 2 Zone 2 SHF-II Series

Class I Division 2

Zone 1&2, Zone 21&22

LED 20-180W

Type 4X, IP66

View More
Explosion Proof Led Flood Light Class 1 Div 2 Zone 2 SHF-IIA Series

Class I Division 2

Zone 2, Zone 21&22

LED 20-400W

Type 4X, IP66

View More
Explosion Proof Led Street Light Class 1 Div 1 Zone 1 SSL Series

Class I Division 1

Zone 1&2, Zone 21&22

LED 80-300W

Type 4X, IP66

View More
Explosion Proof Led Gas Station Canopy Lights Class 1 Div 2 Zone 2 SCP Series

Class I Division 2 

Zone 2, Zone 21&22 

LED 40-150W 

Type 4X, IP66

View More

Features

Explosion Proof Flood Light

  • Die cast aluminum flame proof or increased safety housing

  • Independent chamber for led driver, led lamp and connection

  • Adjustable lighting angle and bracket mounted

  • High lumen output to lighting a large area work place

  • High wattages and lumens efficiency with led lamp

  • Wide voltage power input for different grid

  • Wide ambient temperature range from -40℃ - +55℃

  • IP66, IP67 ingress protection, NEMA 4X

  • Class 1 Div 1, Class 1 Div 2, Class 2 Division 1, Class 2 Division 1

  • Zone 1, Zone 2, Zone 21, Zone 22

Main Use

Explosion Proof Flood Light

Explosion proof flood lighting can be directed to four aspects subject to the features, hazard class division for hazardous area classifications, usage by application for exact application plant names, usage by mounting places for suitable mounting site and alternative for brand-new model.

You can choose different types of flame proof flood light according to your application scenarios and risk factors, so that the product can provide both lighting needs and security.


                  Area


Model

Class DivisionZone
C1D1C1D2C2D1C2D2Zone 1Zone 2Zone 21Zone 22
SHF-I××××××××
SHF-IA
×××
×××
SHF-II××××××××
SHF-IIA
×××
×××
SSL××××××××
SCP
×××
×××
  • Hazard class division

Different classifications and divisions are available for any explosion proof lighting, the same as explosion proof flood lighting, hazard class division can be class 1 div 1 and class div 2, class 2 division 1 and class 2 division 2, zone 1 and zone 2, zone 21 and zone 22, you can check the hazardous area classifications chart as below.


  • Usage by application 

Depends on the application field, explosion proof flood lighting can be used in upstream oil and gas plant, middle-stream refinery and petrochemical plant, energy plant, chemical and pharmaceutical plant and other plants for gas station lights plant, anywhere there is flammable gas, vapor, mist and dust.

Explosion Proof Flood Light Main Use
  • Usage by mounting places

Explosion proof flood lighting can be used in top of oil tower spot, refinery processing areas, roof of buildings, oil tankers, square high ground, side wall areas, access and road for chemical production areas and other areas requesting large scale lighting for hazardous locations.

  • Alternative for brand-new model

SUREALL explosion flood lighting is the alternative lighting solution for evl lighting, ewl lighting, arran lighting, scod lights, arhn lights, prge lighting, ssnr lighting, kflh lights.

Explosion Proof Flood Light Main Use

What Makes A Flood Light Explosion Proof?

When a flood light is protected by strict explosion proof technology, a flood light can be explosion proof.


Once we are talking about a explosion proof flood lighting, high wattages, high lumens, bulky shape will come to our mind because explosion flood lighting should have brilliant heat limit performance with intensive dense fins structure and dead-hard flame proof enclosure to resist the explosion impact when the internal electrical parts explode. Besides, the heat and fire inside the light body will be evacuated properly to eliminate the explosion outside of the light body to guarantee the safety of the project site. In some case, increased safety measures will be made for the electrical circuits to rise the safety level of the whole light for class 1 div 2 and zone 2 classifications, moreover, flame proof isolation is ultra valid to avoid the explosion for led driver chamber, led lamp chamber and connection chamber when electrical sparks and heat present.

What Makes A Flood Light Explosion Proof?
Product

FAQs about Explosion Proof Flood Light

Q

What is hazardous locations light?

A

Hazardous locations light is looked as explosion proof lighting used in hazardous locations for NEC500 standard. Depends on the flammable ingredient group, class 1 means hazardous gas and vapor, class 2 means hazardous dust, class 3 means hazardous fiber. Classified by the frequency the flammable ingredient present in locations, class 1 division 1 means hazardous gas and vapor present intermittently (more than 10 hours every year), class 2 division 1 means hazardous dust present intermittently (more than 10 hours every year), class 1 division 2 means hazardous gas and vapor present abnormally (less than 10 hours every year), class 2 division 2 means hazardous dust present abnormally (less than 10 hours every year). So the hazardous locations light has five types, class 1 division 1 light, class 1 division 2 light, class 2 division 1 light, class 2 division 2 light and class 3 light.

Q

Can LED light explode?

A

No, LED means light-emitting diode, LED light is a light with LED lamp source which only cause high temperature problem in some case. Since LED light are packed in a solid body with special cooling design, it will not produce fire or fire can be impossible to form to be an ignition source, LED light can not explode without any fire or ignition source even through there are flammable substance around. Particularly, explosion proof led light can absolutely not explode when it is applied by explosion proof measures based on general led lights.

FAQs about Explosion Proof Flood Light
FAQs about Explosion Proof Flood Light
Q

Does Class 1 div 2 require explosion proof?

A

Yes, class 1 div 2 require explosion proof. Class 1 div 2 is one of the hazardous locations classification which means the ignitable gas or vapor will produce not normally which is exactly a lower hazardous level, but it is still one kind of hazardous level of explosion proof whose classification intrinsically can be divided into higher level class 1 div 1, lower level class 1 div 2, higher level class 2 div 1, lower level class 1 div 2 and higher level class 3. Thus, class 1 div 2 require explosion proof no matter for what kind of electrical apparatus not limited to explosion proof lighting.

Q

What is the difference between floodlight and spotlight?

A

In simple, spotlight is a part of flood light, when you change the beam angle to a narrow one such as less than 45 degrees, you can call this light a spotlight, while on the contrary, if you adjust the beam angle to a wide one such as more than 45 degrees, you can call this light a floodlight. As for the application difference, you can use a spotlight to an important point like chemical test which have accurate lighting request for the lighting area scope, at the same time, you can use a floodlight for other points which only request rough lighting.

Q

What is the difference between an area light and a flood light?

A

Area light is used for certain working plane or table which is normally a limited and fixed place to exact look for one processing procedure or workmanship, the distance from the working surface to the lighting installation point can be ranging from 10 feet to 60 feet. Flood light is widely used in large area, probably for outdoor opening place, to check the whole site or one big site for overall looking, the lighting beam angle can be adjustable to direct the approximate visual position.

Lighting The Way To Safety! Choose SUREALL, Sure For All!

Want to Get High-quality LED lighting, explosion proof lighting and other explosion-proof fittings? Welcome to SUREALL

SUREALL Latest News & Blog